Download printed
version of program as ![]()
| One Day on The Liver | |||||
Poster Program
| Poster Session 1 Thursday 6th 15:30 - 17:00 p.m. |
Artificial Liver &
Artificial Lung Moderators: K. Mottaghy (Aachen, Germany) , Y. Nose (Houston, USA) |
No. |
| CLINICAL APPLICATION OF ARTIFICIAL LIVER SUPPORT WITH THE MOLECULAR ADSORBENT RECIRCULATING SYSTEM (MARS): IMPACT ON CYTOKINES AND GROWTH FACTORS | 56 | |
| L.Colì, G. Donati, M.L.Cappuccilli, G. Cianciolo, F. Gozzetti, G. Comai, M. Piccari, V. Nastasi, E. Silvagni, F. Piscaglia, L. Bolondi, S. Stefoni (Bologna, Italy) | ||
| A CFD COMPUTATIONAL MODEL FOR THE OPTIMIZATION OF TRANSPORT PHENOMENA IN A HOLLOW FIBER BIOREACTOR FOR ARTIFICIAL LIVER | 57 | |
| F. Consolo, S. Truscello, F.M. Montevecchi, G.B. Fiore, A. Redaelli (Torino, Italy) | ||
| PERITONEAL IMPLANTATION OF CRYOPRESERVED ENCAPSULATED PORCINE HEPATOCYTES IN RATS WITHOUT IMMUNOSUPPRESSION: VIABILITY AND FUNCTION | 58 | |
| R. Cursio, E. Baldini, G. De Sousa, A. Margara, J. Honiger, M-C. Saint-Paul, P. Bayer, V. Raimondi, R. Rahmani, J. Mouiel, J. Gugenheim (Nice, France) | ||
| NUMERICAL STUDY OF O2 CONSUMPTION AND AVAILABILITY IN A FULL-SCALE MODEL OF THE AMC BIOARTIFICIAL LIVER WITH IN VITRO DETERMINED HEPATOCYTE DISTRIBUTION | 61 | |
| G. Mareels, P. Poyck, S. Eloot, R. Chamuleau, P. Verdonck (Gent, Belgium) | ||
| MODIFICATION OF HEPATIC CELL CULTURE SURFACE FOR BIOARTIFICIAL LIVER DEVICE | 63 | |
| A. Kinasiewicz, A. Smietanka, A. Makowska, A. Werynski (Warsaw, Poland) | ||
| BIOARTIFICIAL LIVER SUPPORT: A STANDALONE PERFUSED ROTARY CELL CULTURE SYSTEM | 64 | |
| V. Lubei, M. Wurm, M. Caronna, R. Margreiter, C. Tetta, P. Hengster (Innsbruck, Austria) | ||
| MARS TREATMENT IN HBV PATIENTS IMPROVES MELD SCORE AND FOLLOW-UP A THREE MONTHS | 67 | |
| G. Novelli, L. Poli , V. Morabito, F. Ruberto, G. Mennini, A. Bussotti, F. Antonellis, M. Rossi, P.B. Berloco (Roma, Italy) | ||
| PEDIATRIC ACUTE LIVER FAILURE IN TREATMENT WITH MARS: EXPERIENCE OF UNIVERSITY LA SAPIENZA | 68 | |
| G.Novelli, M. Rossi, L. Poli, F. Pugliese, V. Morabito, A. Bussotti, Q. Lai, P.B. Berloco (Roma, Italy) | ||
| COMPUTATIONAL MODEL SIMULATING ALVEOLAR REOPENING IN THE HUMAN LUNGS | 71 | |
| B. Kuraszkiewicz, M. Darowski (Warsaw, Poland) | ||
| PREDICTIONS OF EPITHELIAL CELL STRESSES DURING AIRWAY REOPENING – MODEL STUDY | 72 | |
| B. Kuraszkiewicz (Warsaw, Poland) | ||
| VIRTUAL CASE STUDY: IMPROVING OF BLOOD OXYGENATION THAT FELL AFTER POSITION CHANGE OF AN OLDER PATIENT | 74 | |
| T. Golczewski, M. Darowski (Warsaw, Poland) | ||
| VIRTUAL LUNGS IN AN INTERACTIVE SYSTEM FOR E-LEARNING OF SPIROMETRY | 75 | |
| T. Gólczewski, M. Michnikowski, W. Tomalak (Warsaw, Poland) | ||
| INFLUENCE OF VENTILATION MODE ON BLOOD OXYGENATION - ANALYSIS WITH LUNGS AND CARDIOVASCULAR MODELS | 76 | |
| T. Golczewski, K. Zieliński, K.J. Palko, G. Ferrari, M. Darowski (Warsaw, Poland) | ||
| THE COMPARISON INVESTIGATIONS OF THE ADDED COMPLIANCE AND END-INSPIRATORY PAUSE METHODS | 77 | |
| K.J. Palko, K. Zielinski, M. Kozarski, M. Darowski (Warsaw, Poland) | ||
| VIRTUAL THERAPIST AS A COMPUTER TOOL FOR THE REDUCTION OF RESPIRATORY DISTURBANCES IN STUTTERING | 78 | |
| B. Stankiewicz, K. Zielinski, B. Adamczyk, M. Darowski (Warsaw, Poland) | ||
| ARTIFICIAL VENTILATION VIA VARIOUS-SHAPED INFANT ENDOTRACHEAL TUBES. IN VITRO STUDY | 79 | |
| B. Stankiewicz, J. Glapinski, M. Darowski, M. Rawicz, B. Woloszczuk-Gebicka, M. Guć, M. Michnikowski (Warsaw, Poland) | ||
| ENCAPSULATION OF C3A CELLS INTO ALGINATE MICROCAPSULES FOR THE POTENTIAL USE IN A BIOARTIFICIAL LIVER DEVICE | 209 | |
| J. Hartmann, S. Harm, K. Strobl, D. Falkenhagen (Krems, Austria) | ||
| Poster Session 1 Thursday 6th 15:30 - 17:00 p.m. |
Biomaterials Moderators: T. Groth (Halle, Germany) , G. von Sengbusch (St. Dionys, Germany) |
No. |
| PLANIMETRIC ANALYSIS OF IMPLANTED ELECTROSPUN PDS-PLA GRAFTS IN THE RAT SYSTEMIC ARTERIAL CIRCULATION | 85 | |
| M. Cikirikcioglu, R. Pfister, E. Pektok, J.C. Tille, A. Kalangos, G. Bowlin, B.H. Walpoth (Geneve, Switzerland) | ||
| FUNCTIONAL CHARACTERIZATION OF ELECTROSPUN POLY(E-CAPROLACTONE) HEART VALVE FOR TISSUE ENGINEERING APPLICAITONS | 87 | |
| M. Grigioni, C. Del Gaudio, A. Bianco (Rome, Italy) | ||
| DYNAMIC LOCAL MECHATRONIC PROPERTY MEASUREMENT OF COAGULATION WITH MICRO VIBRATING ELECTRODE | 88 | |
| S. Hashimoto, S. Mochizuki, D. Inoue, M. Okada, T. Miyazaki, T. Sahara, K. Yamasaki, H. Kondo, T. Fujisato, H. Otani, H. Imamura, T. Iwasaka (Osaka, Japan) | ||
| RELEASING OF LEUPROLIDE ACETATE LOADED ON AN IN SITU FORMING SYSTEM | 90 | |
| R. Mashayekhi, H. Mobedi (Tehran, Iran) | ||
| CHARACTERIZATION OF WET PS/PVP FILM SURFACES BY ATOMIC FORCE MICROSCOPY | 91 | |
| M. Matsuda, K. Yamamoto, T. Yakushiji, M. Fukuda, T. Miyasaka, K. Sakai (Tokyo, Japan) | ||
| ALBUMIN-HEPARIN COATED DIAION PA408 ANION EXCHANGE RESIN FOR PSAF ARTIFICIAL LIVER SYSTEM | 94 | |
| C. Mun, B. Min, K. Lim, S. Lee (Seoul, Korea) | ||
| CARBONIC SORBENTS FOR BLOOD PURIFICATION: NEW PRINCIPLES AND APPROACHES | 95 | |
| V.G. Nikolaev, V.V. Sarnatskaya, S.V. Mikhailovskiy, K.I. Bardakhivskaya, E.A. Snezkova, L.A. Yushko, L.A. Sakhno, V.N. Maslenny, Sh.Z. Kasymov, A.S. Sidorenko, A.V. Nikolaev (Kiev, Ukraine) | ||
| TISSUE REPAIR USING CELL SEEDED SCAFFOLDS | 97 | |
| U. Nydegger, M. Siepe, H. Jenzer, H. Tevaearai, (Bern, Switzerland) | ||
| DEVELOPMENT OF A NOVEL AQUEOUS ANTITHROMBOGENIC COATING MATERIAL: HEPARIN BIOCONJUGATE WITH A THERMORESPONSIVE STAR POLYMER | 99 | |
| R. Okahashi, R. Iwai,, K. Uchida, Y. Nemoto, Y. Nakayama (Osaka, Japan) | ||
| BIOCOMPATIBILITY EVALUATION OF BIODEGRADABLE MATRIXES TREATED BY VACUUM ULTRAVIOLET IRRADIATION | 101 | |
| E. A. Remeeva, I. B. Rozanova, V.I. Sevastianov (Moscow, Russia) | ||
| BIOPHOTOPOLYMERS FOR HARD TISSUE REPLACEMENT | 102 | |
| M. Schuster , C. Turecek, J. Stampfl, F. Varga, R. Liska (Vienna, Austria) | ||
| EVALUATION OF BIOPHOTOPOLYMERS FOR BONE REPLACEMENT MATERIALS CAPABLE FOR RAPID PROTOTYPING | 104 | |
| C. Turecek, M. Schuster, S. Baudis, R. Liska, J. Stampfl, F. Varga (Vienna, Austria) | ||
| THE DEPOSITION TRANSFECTION TECHNOLOGY USING A DNA COMPLEX WITH A THERMORESPONSIVE STAR POLYMER | 106 | |
| Y.M. Zhou, R. Okahashi, A. Ishikawa, K. Uchida, Y. Nemoto, M. Nakayama, Y. Nakayama (Osaka, Japan) | ||
| ARTIFICIAL CARRIER FOR NANOPARTICLES – TARGETED DELIVERY OF DRUGS | 195 | |
| H. Bäumler, M. Brähler, R. Georgieva, A. Höning, A. Müller, M. Müller, J. Pinkernelle, U. Teichgräber (Berlin, Germany) | ||
| TOXICITY TEST OF LUMINESCENT NANOCRYSTALLINE SILICON PARTICLES | 197 | |
| M. Hiruoka, K. Sato, K. Hirakuri, K. Fujioka, K. Yamamoto (Tokyo, Japan) | ||
| Poster Session 1 Thursday 6th 15:30 - 17:00 p.m. |
Fluid Dynamics, Modelling &
Simulation Moderators: E. Leonard (New York), P. Verdonck (Gent, Belgium) |
No. |
| ANALYSIS OF MICRO FLUID DYNAMICS AND METABOLITES TRANSPORT IN SCAFFOLDS FOR HAEMATOPOIETIC STEM CELL CULTURE | 135 | |
| M. Cantini, G.B. Fiore, A. Redaelli, M. Soncini (Milan, Italy) | ||
| CAVOPULMONARY CONNECTION WITH TWO SUPERIOR VENAE CAVAE: STUDY OF THE OPTIMAL VEINS-TO-ARTERIES INXERTION ANGLE | 138 | |
| M. Grigioni, C. Del Gaudio, G. D’Avenio, S. Donatiello, A. Amodeo (Rome, Italy) | ||
| AN INVESTIGATION ON THE PULSE WAVE PROPAGATION IN BLOOD VESSELS | 140 | |
| G. Pallotti, P. Pettazzoni, M. Slawomirski, M.G. Bernardi, F. Burrai, E. Caroli (Bologna, Italy) | ||
| USEFULNESS AND LIMITATION IN PREDICTION OF A SHIFT IN A FUTURE NUMBER OF JAPANESE MAINTENANCE HEMODIALYSIS PATIENTS BY APPLYING A DYNAMIC ANALYSIS OF COMPUTER-APPROXIMATING MATHEMATICAL MODELS | 156 | |
| T. Agishi, S. Kikuchi, T. Sato, N. Kawashima (Tokyo, Japan) | ||
| DEVELOPMENT OF EXPERIMENTAL HEART FAILURE MODEL IN THE GOATS INDUCED BY RAPID VENTRICULAR PACING WITH LEFT VENTRICULAR ASSIST DEVICES | 157 | |
| A. Baba, Y. Shiraishi, Y. Saijo, K. Sekine, H. Liu, I. Saito, P. Dobšák, Y. Abe, T. Yambe, T. Toyo-oka, J. Vašků, K. Imachi (Sendai, Japan) | ||
| USER FRIENDLY SELF-TUNING CIRCULATORY MODEL: A TOOL FOR CLINICAL, RESEARCH AND EDUCATIONAL APPLICATIONS | 159 | |
| G. Ferrari, M. Kozarski, Y.J. Gu, K.J. Palko, K. Zieliński, K.Górczyńska, M. Darowski, G. Rakhorst (Rome, Italy) | ||
| MODELING OF THE ENDOVENTRICULAR SHAPER | 162 | |
| Z. Malota, Z. Nawrat, T. Kukulski , P. Kostka (Zabrze, Poland) | ||
| A LUMPED PARAMETER MODEL TO DESCRIBE THE UNCONTROLLED PULSATILITY IN ROLLER PUMP | 163 | |
| F. Moscato, F. M. Colacino, M. Arabia, G. A. Danieli (Rende, Italy) | ||
| DEVELOPMENT OF AN ANATOMICALLY IDENTICAL SILICONE CAROTID BIFURCATION MODEL WITH ARTIFICIAL PLAQUE AND IT’S APPLICATION FOR STENTING TECHNIQUE | 164 | |
| Y. Okamoto, H. Yamaga, H. Yada, T. Tanaka, H. Kobashi, T. Terada, T. Itakura, K.Iwasaki, M. Umezu (Tokyo, Japan) | ||
| REMOTE CONTROL SYSTEM FOR CARDIOVASCULAR MODELLING IN REAL-TIME APPLICATIONS | 165 | |
| K.J. Palko, G. Ferrari, K. Zielinski, K. Gorczynska, M. Kozarski, M. Darowski (Warsaw, Poland) | ||
| VISCOELASTIC AND PIEZOELECTRIC PROPERTIES OF BONE: A STUDY MODEL | 166 | |
| G. Pallotti, P. Pettazzoni, M. Nichelatti, E. Caroli (Bologna, Italy) | ||
| A VARIABLE TIME-VARYING ELASTANCE APPLIED IN A HYBRID MODEL OF THE LEFT VENTRICLE | 167 | |
| M. Kozarski, G. Ferrari, K. Zielinski, K. Gorczynska, K.J. Palko, A. Tokarz, M. Darowski (Warsaw, Poland) | ||
| A LIQUID-LIQUID-SYSTEM AS A MODEL FOR BLOOD FLOW IN CAPILLARIES | 199 | |
| K. Schirrmann, U. Kertzscher, L. Goubergrits, W.M. Kübler, K. Affeld (Berlin, Germany) | ||
| Poster Session 1 Thursday 6th 15:30 - 17:00 p.m. |
Tissue Engineering Moderators: S. Nehrer (Krems, Austria) , B. Walpoth (Geneva, Switzerland) |
No. |
| DECELLULARIZED PORCINE VALVE SCAFFOLDS MODIFIED WITH CARBODIIMIDE FOR HEART VALVE TISSUE ENGINEERING | 169 | |
| A. Baranska, B. Irzyk, J. Nożyński, A. Majkusiak, P. Wilczek, R. Wojnicz (Zabrze, Poland) | ||
| COMPLEMENT-MEDIATED NEUTROPHIL ADHESION AND ACTIVATION ON DECELLULARIZED PORCINE HEART VALVE TISSUE | 170 | |
| F. Bastian, M. Stelzmüller, E. Rieder, E. Eichmair, MT. Kasimir, P. Simon, G. Weigel (Vienna, Austria) | ||
| THE EFFECT OF OXYGEN AS A TOOL TO VALIDATE PRIMARY CALF OSTEOBLASTS AS AN IN VITRO MODEL FOR BONE TE | 173 | |
| I. De Napoli, G. Catapano (Rende, Italy) | ||
| DETOXIFICATION AND ENDOTHELIALIZATION OF GLUTARALDEHYDE FIXED COLLAGEN SCAFFOLDS FOR CARDIOVASCULAR TISSUE ENGINEERING | 174 | |
| N.W. Guldner, I. Jasmund, V. Mayer, H. Gebert, M. Heinlein, H. Sievers (Luebeck, Germany) | ||
| IN VITRO HYDRODYNAMIC FUNCTIONS OF “BIOVALVES” - MECHANICAL COMPATIBILTY BEFORE IMPLANTATION | 177 | |
| K. Kanda, K. Hayashida, M. Onoyama, T. Tajikawa, K. Ooba, T. Ooie, Y. Okamoto, Y. Nemoto, H. Ueda, H. Yaku, Y. Nakayama (Kyoto, Japan) | ||
| THE USE OF ARTIFICIAL SUBLAYER FOR THE GROWTH OF FIBROBLASTS IN CORRECTION OF THE DERMAL DEFECTS | 178 | |
| V. Zaporozhan, O. Kholodkova, D. Pykhtyeyev (Odessa, Ukraine) | ||
| MYOCARDIAL EXTRACELLULAR MATRIX NORMALIZATION BY ELECTRICAL MICROCURRENT APPLICATION IN VIVO. BASICS FOR A NOVEL HEART FAILURE TREATMENT | 179 | |
| J. Mueller, B. Kapeller, U. M. Losert, K. Macfelda (Berlin, Germany) | ||
| DEVELOPMENT OF ENDOVASCULAR STENT COVERED WITH BIODEGRADABLE SALMON COLLAGEN | 181 | |
| N. Nagai, Y. Nakayama, K. Mori, S. Yunoki, M. Munekata (Hokkaido, Japan) | ||
| REGENERATION OF CENTRAL NERVOUS TISSUE USING A COLLAGEN SCAFFOLD AND ADIPOSE DERIVED STROMAL CELLS | 182 | |
| A. Nakada, S.Fukuda, S. Ichihara, S. Itoi, Y. Inada, K. Endo, T. Nakamura (Kyoto, Japan) | ||
| CONTROL OF MECHANICAL STIMULATION OF 3-DIMENSIONAL CONSTRUCTS IN A BIOREACTOR | 185 | |
| A. Runtemund, C. Haasper, B. Glasmacher, M. Jagodzinski (Hannover, Germany) | ||
| DEVELOPMENT OF THE AUTOLOGOUS TISSUE-COVERED STENT “BIOCOVERED STENT” - PILOT ANIMAL IMPLANTATION EXPERIMENTS | 186 | |
| O. Sakai, K. Kanda, K. Hayashida, H. Yaku, Y. Nakayama (Osaka, Japan) | ||
| INJECTABLE, BIODEGRADABLE POLY (DL-LACTIDE-CO-GLYCOLIDE) CARBOXYL TERMINATED FOR CARTILAGE TISSUE ENGINEERING: IN VIVO | 187 | |
| A. Solouck, H.Mirzadeh, H. Yeganeh (Tehran, Iran) | ||
| RIFAMPIN AND TANNIC ACID TREATMENT OF PORCINE PERICARDIUM | 188 | |
| A. Turek, B. Cwalina, L. Pawlus-Lachecka, J. Nozynski, Z. Dzierzewicz (Sosnowiec, Poland) | ||
| THE INFLUENCE OF TEMPERATURE ON TISSUE STRUCTURE DURING PERICARDIUM STERILIZATION BY ANTIBIOTICS | 189 | |
| A. Turek, B. Cwalina, L. Pawlus-Lachecka, Z. Dzierzewicz (Sosnowiec, Poland) | ||
| DESIGN AND PRELIMINARY TEST OF A NEW BIOREACTOR FOR DYNAMIC CULTURE OF AORTIC VALVE CONSTRUCTS | 190 | |
| R. Vismara, M. Soncini, L. Dainese, A. Guarino, A. Redaelli, G.B. Fiore (Milan, Italy) | ||
| IMPORTANCE OF FLOW IN ENDOTHELIAL-SPECIFIC INVESTIGATIONS CONCERNING SEPSIS | 212 | |
| D. Schwanzer-Pfeiffer, E. Rossmanith, K. Hellevuo, D. Falkenhagen (Krems, Austria) | ||
| EVALUATION OF REGENERATIVE MEDICINE/TISSUE ENGINEERING APPROACHES BY HEALTH TEHCHNOLOGY ASSESSMENT | 217 | |
| E. Falkner, C. Eder, C. Wild (Vienna, Austria) | ||
| IMPLEMENTATION OF ECIS TECHNOLOGY FOR THE IDENTIFICATION OF POTENTIAL WOUND-HEALING PROMOTING SUBSTANCES | 218 | |
| C. Wiesner, J. Kopecky, M. Pflüger, H. Hundsberger, D. Stys, B. Entler, C. Kleber, R. Lucas, W. Schütt (Krems, Austria) | ||
| Poster Session 2 Friday 7th 15:30 - 17:00 p.m. |
Artificial Heart & Cardiac
Assist Moderators: J. F. Del Canizo (Madrid, Spain) , H. Schima (Vienna, Austria) |
No. |
| TIME RESOLVED PIV VENTRICULAR FLOW FIELD STUDY OF DIFFERENTLY DESIGNED CONTEMPORARY BI-LEAFLET MITRAL VALVES | 8 | |
| T. Akutsu, T. Fukuda, J. Saito (Yokohama, Japan) | ||
| PULSATILE LVAD IN A PIG EXPERIMENTAL MODEL: LEFT VENTRICLE-LVAD SYNCHRONICITY PRELIMINARY STUDY | 9 | |
| R. Pérez-Caballero, A. Heredero-Jung, H. Rodríguez-Abella,G. Cuerpo-Caballero, J. López-Menéndez, A. Donado,B. Quintana, J.J. Gomez de Diego, D. Rodríguez Martínez, A. González-Pinto (Madrid, Spain) | ||
| TORQUE MEASUREMENTS ON CARDIOVASCULAR IMPLANTS IN NMR SCANNERS: A RELIABLE METHOD FOR RISK ANALYSIS AS FROM ISO EN 14971 | 10 | |
| M. Grigioni, G. D’Avenio, R. Canese, F. Podo (Rome, Italy) | ||
| STEREO PIV ON MECHANICAL HEART VALVE PROSTHESIS TESTED ON THE RWTH PULSE DUPLICATOR | 11 | |
| M. Grigioni, G. D’Avenio, K. Hamilton, U. Morbiducci, U. Steinseifer (Rome, Italy) | ||
| CFX-SIMULATION OF INFLUENCE OF VALVES ON HEMODYNAMICS IN ARTIFICIAL VENTRICLE WITH MEMBRANE | 13 | |
| V.V. Morozov, A.V. Zhdanov, N.S. Provorova (Vladimir, Russia) | ||
| THE EFFECT OF SHAPE AND ANGLE ON INTRA-AORTIC BALLOON PUMP PERFORMANCE | 108 | |
| G. Biglino, C. Kolyva, M. Whitehorne, J.R. Pepper and AW. Khir (Uxbridge, UK) | ||
| LOW COST PULSATILE CARDIAC ASSIST DEVICE | 109 | |
| D. Rodríguez-Martínez, A. del Cañizo, J.F. Del Cañizo (Madrid, Spain) | ||
| ENDOTHELIUM–DERIVED NITRIC OXIDE PRODUCTION DURING CARDIOVASCULAR SURGERY: COMPARISON BETWEEN CONTINUOUS CARDIOPULMONARY BYPASS AND BEATING HEART SURGERY | 114 | |
| E. Lanzarone, A. Fumero, F. Gelmini, M. Orioli, M. D’Arienzo, R. Scotti, G. Aldini, F. Morazzoni, M. Carini, M.L. Costantino, R. Fumero (Milan, Italy) | ||
| ELECTRO-HYDRAULIC DRIVER DESIGN FOR A DUAL-PULSATION BI VENTRICULAR ASSIST DEVICE | 116 | |
| P.J. Lu, M.Y Chan, T.C. Hsu, P.Y. Lin (Tainan, Taiwan) | ||
| AXIAL FLOW VAD CONTROL STRATEGY TO REDUCE THE LEFT VENTRICLE AFTERLOAD IMPEDANCE AND HELP PERFUSION | 118 | |
| F. Moscato, F.M. Colacino, M. Vollkron, H. Schima, M. Arabia,G. A. Danieli (Rende, Italy) | ||
| AUTOMATED FREQUENCY-CONTROLLED WIRELESS POWER TRANSFER FOR IMPLANTABLE MEDICAL DEVICES | 119 | |
| T. Mussivand, A. Mizannojehdehi, M. Shams (Ottawa, Canada) | ||
| ASSESSMENT OF CARDIAC FUNCTION FOR MICROMED-DEBAKEY VAD® RECIPIENTS | 120 | |
| P. Naiyanetr, M. Vollkron, D. Zimpfer, S. Sandner, G. Wieselthaler, H. Schima (Vienna, Austria) | ||
| A SHUNT MODEL TO ASSESS HEALING PATTERNS OF CANNULAE DESIGNED FOR CIRCULATORY SUPPORT | 123 | |
| F. Rega, H. Bollen, I. Vantichelen, O. Marseille, R. Farnan, M. Martin, B. Meyns, E. Verbeken (Leuven, Belgium) | ||
| IN VIVO EVALUATION OF A NEW IMPLANTABLE, PULSATILE LVAD | 125 | |
| P. Ferrazzi, M. Glauber, N. Borenstein, L. Behr, S. Rinaldi (Bergamo, Italy) | ||
| FUNCTIONAL IMPROVEMENT OF AN NEWLY-DEVELOPED MYOCARDIAL ASSIST DEVICE USING SHAPE MEMORY ALLOY FIBRES | ||
| Y. Shiraishi, T. Yambe, Y. Saijo, K. Matsue, H. Liu, S. Nitta, A. Baba, K. Imachi, Y. Wada, R. Sakata, T. Tanaka, M. Uematsu, Y. Park, M. Umezu, A. Tanaka, M. Yoshizawa, F. Sato, K. Sekine, T. Fujimoto, H. Sasada, K. Tabayashi, E. Okamoto, D. Homma (Sendai, Japan) | 127 | |
| PULSE WAVE VELOCITY DURING CIRCULATORY ASSISTANCE WITH UNDULATION PUMP VENTRICULAR ASSIST DEVICE (UPVAD) | 128 | |
| T. Yambe, Y. Luo, M. Yoshizawa, S. Nitta, K. Imachi, Y. Abe (Sendai, Japan) | ||
| NEW ARTIFICIAL ORGAN = HYPERTHERMIA DRINKING STENT | 201 | |
| T. Yambe, Y. Shiraishi, K. Sekine, G. Miyata, S. Satomi (Sendai, Japan) | ||
| HOLOGRAPHIC DISPLAY AS INNOVATIVE TRAINING TOOL | 203 | |
| G. D’Avenio, T. Balogh, M. Grigioni (Roma, Italy) | ||
| THE COMPLETELY IMPLANTABLE DLR ASSIST DEVICE: SYSTEM INNOVATIONS AND IMPROVEMENTS | 211 | |
| T. Schmid, W. Schiller, B. Vodermayer, D. Liepsch, A. Welz, G. Hirzinger (Wessling, Germany) | ||
| Poster Session 2 Friday 7th 15:30 - 17:00 p.m. |
Aritifcial Kidney Moderators: H. Holzer (Graz, Austria) , H. Mann (Aachen, Germany) |
No. |
| KINETICS OF PLASMA POTASSIUM DURING AND AFTER HAEMODIALYSIS IN PATIENTS WITH CHRONIC RENAL DISEASE | 18 | |
| Z. Antova, L.Tozija, K. Cakalaroski (Skopje, Macedonia) | ||
| THE INFLUENCE OF FISTULA BLOOD FLOW RATE ON DIALYSIS ADEQUACY IN MAINTENANCE HEMODIALYSIS PATIENTS | 27 | |
| P. Dzekova, P. Dejanov, V. Gerasimovska, A. Asani, S. Pavleska, G. Selim, S. Gelev, V. Amitov, A. Oncevski, A. Sikole (Skopje, Macedonia) | ||
| REMOVAL OF METHOTREXATE (MTX) IN ANURIC PATIENT: A CASE REPORT | 29 | |
| A. Villani, M. Ferrannini, E. Staffolani, G. Vischini, N. Miani, S. Condò, N. Di Daniele (Rome, Italy) | ||
| ARTERIAL DISEASE IN ASYMPTOMATIC HEMODIALYSIS PATIENTS | 31 | |
| S. Gelev, G. Spasovski, S. Dzikova, S. Tosev, M. Bosevski, G. Selim, P. Dzekova, A. Asani, V. Amitov, A. Sikole (Skopje, Macedonia) | ||
| GLUCOSE INFLUENCE ON SMALL AND LARGE MOLECULES PERITONEAL TRANSPORT: COMPARATIVE STUDIES IN VITRO | 32 | |
| T. Grzelak, B. Szary, K. Czyżewska (Poznan, Poland) | ||
| HEMODIAFILTRATION AND HIGH-FLUX HEMODIALYSIS SIGNIFICANTLY REDUCE SERUM VALPROATE LEVELS INDUCING EPILEPTIC SEIZURES: CASE REPORT | 33 | |
| J. Gubensek, R. Ponikvar, B. Cebular, J. Buturovic-Ponikvar (Ljubljana, Slovenia) | ||
| REGIONAL CITRATE ANTICOAGULATION FOR SINGLE-NEEDLE HEMODIALYSIS: A PROSPECTIVE CLINICAL STUDY | 34 | |
| J. Gubensek, J. Buturovic-Ponikvar, R. Ponikvar (Ljubljana, Slovenia) | ||
| CITRATE ANTICOAGULATION FOR POSTDILUTIONAL ON-LINE HEMODIAFILTRATION WITH CALCIUM CONTAINING DIALYSATE/INFUSATE | 35 | |
| J. Buturovic-Ponikvar, J. Gubensek, R. Ponikvar (Ljubljana, Slovenia) | ||
| FLOW ANALYSIS ON HOLLOW FIBER DIALYZER: COMPUTATIONAL MODELING AND COMPUTERIZED TOMOGRAPHY IMAGE PROCESSING | 36 | |
| J.C. Kim, J.H. Kim, J.Y. Park, B.G. Min (Seoul, Korea) | ||
| PREDICTION OF TOXIN CLEARANCE BY DETECTING CONDUCTIVITY OF DIALYSIS SOLUTION USING SINGLE ALTERNATING CURRENT FREQUENCY VOLTAGE | 37 | |
| W.H. Kang, S.M. Lee, D.S. Choi, K.M. Lim, B.G. Min (Seoul, Korea) | ||
| IN VIVO TEST OF THE COLD DIALYSATE RECYCLING SYSTEM | 38 | |
| J.H. Kim, J.C. Kim, K.K. Lee, Y.M. Yoon, B.G.Min (Seoul, Korea) | ||
| PATIENTS WITH SYSTEMIC LUPUS ERYTHEMATOSUS, END STAGE RENAL DISEASE AND PATIENTS ON HAEMODIALYSIS: EXTRARENAL DISEASE ACTIVITY | 41 | |
| M. Milovanceva Popovska, L. Grcevska, S. Dzikova, V. Ristovska, A. Sikole, M. Polenakovic (Skopje, Macedonia) | ||
| HEMOSTASIOLOGIC EFFECTS OF ALPHA-1-ACID GLYCOPROTEIN IN ACUTE RENAL FAILURE | 42 | |
| M.V. Osikov, E.V. Makarov, L.V. Krivohizhina (Chelyabinsk, Russia) | ||
| SUCCESSFUL PREGNANCY IN AN UREMIC PATIENT TREATED WITH SINGLE NEEDLE HAEMODIALYSIS | 45 | |
| N. Miani, M. Ferrannini, E. Staffolani, G. Vischini, A. Naticchia, F.M. D’Ascenzo, N. Di Daniele (Rome, Italy) | ||
| PLATELET DYSFUNCTION IN CHRONIC RENAL FAILURE | 47 | |
| M.V. Osikov, V.J. Akhmatov, L.V. Krivohizhina (Chelyabinsk, Russia) | ||
| ANAEMIA AND CARDIOVASCULAR MORTALITY IN HEMODIALYSIS PATIENTS: THE ROLE OF INFLAMMATION AND MALNUTRITION | 50 | |
| G. Selim, O. Stojceva-Taneva, V. Amitov, S. Gelev, P. Dzekova, A. Asani, S. Pavleska, A. Sikole (Skopje, Macedonia) | ||
| VASCULAR ACCESS IN CRITICALLY ILL PATIENTS WITH ACUTE KIDNEY INJURY (AKI) TREATED WITH HEMODIALYSIS/HEMOFILTRATION | 52 | |
| R. Ponikvar, N. Škofic, J. Kovač, V. Premru, B. Knap, M. Benedik, J. Varl, J. Buturović (Ljubljana, Slovenia) | ||
| HYDRATION STATUS AND OVERHYDRATION IN HD PATIENTS – A EUROPEAN MULTICENTRE STUDY | 55 | |
| J. Vlasak, P. Taborsky, P. Ponce, T. Jirka, P. Wabel, R. Wojke (Sokolov, Czech Republic) | ||
| L-CARNITINE AND ERYTROPOIETIN TREATMENT IN HEMODIALYSIS PATIENTS | 202 | |
| B. Dejanova, P. Dejanov, A. Sikole (Skopje, Macedonia) | ||
| AUTOMATIC SYSTEM FOR REGIONAL CITRATE-CALCIUM ANTICOAGULATION | 207 | |
| M. Brandl, K. Strobl, J. Hartmann, K.H. Kellner, D. Falkenhagen (Krems, Austria) | ||
| OPTIMIZATION OF CITRATE ANTICOAGULATION | 210 | |
| J. Hartmann, K. Strobl, U. Fichtinger; D. Falkenhagen (Krems, Austria) | ||
| Poster Session 2 Friday 7th 15:30 - 17:00 p.m. |
Artificial Organs -
Miscellaneous (Artificial Pancreas, Cell Therapy, Plasmapheresis, Tissue
Engineering) Moderators: B. Glasmacher (Hannover, Germany), W. Schütt (Krems, Austria) |
No. |
| THE EFFECTS OF GRANULOCYTE AND MONOCYTE ADSORPTION APHERESIS ON PERIPHERAL BLOOD MONOCYTES IN THE TREATMENT OF ULCERATIVE COLITIS | 5 | |
| H. Schulze, G. Waitz, D. Koczan, Ä. Glass, S. Petermann, W. Ramlow, S. Liebe, J. Emmrich (Rostock, Germany) | ||
| A NEW DEVICE FOR MONITORING OF FOOT WOUNDS HEALING | 80 | |
| P. Foltynski, P. Ladyzynski, K. Migalska-Musial, G. Rosinski, J. Krzymien, J. M. Wojcicki (Warsaw, Poland) | ||
| ATORVASTATIN (A) DID NOT IMPROVE THE METABOLIC VARIABLES DIFFERENTLY IN PATIENTS WITH SEVERE RENAL IMPAIRMENT AND DIABETES MELLITUS (DM) THAN IN THOSE WITHOUT DIABETES | 81 | |
| B. Holmberg, M. Brännström, B. Bucht, E. Dimeny, A. Ekspong, B. Granroth, K.C.Gröntoft, H. Hadimeri, B. Ingman, G. Johansson, K. Lindberger, L. Lundberg, L. Mikaelsson, E. Olausson, B. Persson, A.M. Wikdahl, C. Andersson, B. Stegmayr (Umeå, Sweden) | ||
| IMPACT OF MICROENCAPSULATION ON PIG ISLETS IN LONG-TERM CULTURE | 82 | |
| J. Kinasiewicz, M. Antosiak-Iwanska, M. Sabat, E. Godlewska, E. Sitarek, T. Orlowski (Warsaw, Poland) | ||
| IMMORTALIZATION, SELECTION AND STANDARDIZATION OF A PROGENITOR HEPATIC CELL | 130 | |
| S. Buttiglieri, V. Fonsato, M. B. Herrera, M. Caronna, C. Tetta, G. Camussi (Torino, Italy) | ||
| RECOVERY OF VISUAL RESPONSES BY AAV-MEDIATED CHANNELOPSIN-2 GENE TRANSFER IN GENETICALLY BLIND RCS RATS | 131 | |
| M. Tamai, H. Tomita, M. Sugano (Sendai, Japan) | ||
| PHOTO CROSS-LINKED STAR VECTOR FOR HIGH EFFICIENT GENE DELIVERY | 133 | |
| Y. Nemoto, Y.M. Zhou, Y. Nakayama (Yokohama, Japan) | ||
| IMPACT OF DONOR LIVER CHARACTERISTICS ON THE CELL FUNCTION OF PRIMARY HUMAN HEPATOCYTES | 134 | |
| F.W.R. Vondran, E. Katenz, R. Schwartlander, M.H. Morgul, N. Raschzok, X. Gong, X. Cheng, P. Neuhaus, I.M. Sauer (Berlin, Germany) | ||
| ROBIN HEART VISION: TELEMANIPULATOR FOR CAMERA HOLDING – EVALUATION OF FUNCTIONALITY, USER ERGONOMIC AND PATIENT SAFETY | 141 | |
| Z. Nawrat, P. Kostka, K. Rohr, Z. Małota (Zabrze, Poland) | ||
| ERYTHROCYTES USED AS BIOREACTORS: CHARACTERIZATION OF THE TEST SUSPENSION | 143 | |
| G. Casagrande, R. Fumero, M.L. Costantino (Milan, Italy) | ||
| DEVELOPMENT OF MINIATURE-SIZED PRESSURE SENSOR FOR IMPLANTING IN ARTIFICIAL ORGANS | 145 | |
| T. Fujimoto, Y. Tanaka, S. Nakano, M. Akiyama, S. Nakamura, Y. Takehana, M. Umezu (Tokyo, Japan) | ||
| SURVIVAL ANALYSIS OF ESCHERICHIA COLI ENCAPSULATED IN A HOLLOW FIBER MEMBRANE TREATED WITH TETRACYCLINE, IN VITRO OR IN VIVO | 147 | |
| L.H. Granicka, J. Żołnierowicz, A. Weryński, J. Kawiak (Warsaw, Poland) | ||
| ADVISORY SYSTEM WITH DATABASE TO SUPPORT PATIENTS WITH CARDIO-VASCULAR PROTHEASES. GATHERING AND PROCESSING MULTI-SOURCE INFORMATION – PILOT STUDY | 148 | |
| P. Kostka, Z. Nawrat (Zabrze, Poland) | ||
| MAGNESIUM URINARY EXCRETION IN RELATION WITH PROSTAGLANDINS AND PARATHYROID HORMONE IN PREECLAMPSIA | 151 | |
| L. Lozance, K. Zafirovska, S. Bogdanovska, B. Gerasimovska-Kitanovska, G. Severova, V. Malevska (Skopje, Macedonia) | ||
| A PRESSURE-ADJUSTABLE ARTIFICIAL SPHINCTER FOR OSTOMATES | 152 | |
| Y. Luo,S. Amae, Y. Zhang, T. Yambe, T. Takagi (Sendai, Japan) | ||
| DEVELOPMENT OF REAL-TIME VISUAL RECOGNITION SYSTEM (RTVRS) FOR SCRUB NURSE ROBOT (SNR) AND ASSESSMENT OF PERFORMANCE OF RTVRS-DRIVEN SNR DURING EXCHANGE OF SURGICAL INSTRUMENTS | 153 | |
| F. Miyawaki, K. Ohnuma, K. Yoshimitsu, K. Masamune, Y. Fukui (Saitama, Japan) | ||
| INFLUENCES OF OPERATING CONDITIONS OF THE MICRODIALYSIS TECHNIQUE ON EFFICIENCY OF MONITORING OF THE INTENSIVE TREATMENT OF DIABETIC KETOACIDOSIS (DKA) AND HYPERGLICEMIC HYPEROSMOLAR STATE (HHS) | 196 | |
| A. Ciechanowska, P. Ladyzynski, S. Sabalinska, M. Gutowska, J.M. Wojcicki (Warsaw, Poland) | ||
| DEVELOPMENT AND APPLICATION OF MAGNETIC FLUORESCENT MICROPARTICLES AS MARKERS FOR PARTICLE TRANSFER IN THE MICROSPHERES-BASED DETOXIFICATION SYSTEM | 208 | |
| M. Ettenauer, T. Posnicek, I. Linsberger, M. Brandl, V. Weber, D. Falkenhagen (Krems, Austria) | ||
| IN VITRO CHARACTERIZATION OF THE REDESIGNED MITIHEARTTM LVAD | 215 | |
| A.Z. Hunsberger, Z. Ren, S. Jahanmir, H. Heshmat, M. Tomaszewski, J. Walton (Gaithersburg, USA) | ||
| Poster Session 2 Friday 7th 15:30 - 17:00 p.m. |
SURFACE DEGRADATION OF PUR BASED VASCULAR ACCESS CATHETERS IN AQUEOUS LOCK SOLUTIONS LEADING TO ENHANCED COAGUALTION AND BIOFILM DEPOSITION CAN BE PREVENTED BY A SPECIFIC REACTIVE COATING | 216 |
| A. Schnell, R. Dietrich, S. Hagg, U. Haug, U. Ruhl, R. Deppisch (Hechingen, Germany) | ||
| AUTOTRANSFUSION OF ULTRAVIOLET – IRRADIATED BLOOD IN THE TREATMENT OF CHRONIC DERMATOSES | 219 | |
| V.N. Korol (Kiev, Ukraine) | ||
| APPLICATION OF HYPNOSUGGESTIVE PSYCHOTHERAPY IN BEFORE-PERFUSIVE PREPARATION OF PATIENTS | 220 | |
| E.G. Korol, V.N. Korol (Kiev, Ukraine) | ||